Magnetic Coded Safety Switches Non-Contact
MPSS series Magnetic safety switches Description MPSS series safety switches are magnetically operated, non-contact safe
Send your inquiryDESCRIPTION
Basic Info
Model NO. | MPSS Series |
Housing | Stainless Steel SUS316L |
Transport Package | Carton |
Trademark | Yuanben |
Origin | Shanghai |
HS Code | 85299050 |
Production Capacity | 50, 000PCS/Year |
Product Description
MPSS series Magnetic safety switches
Description
MPSS series safety switches are magnetically operated, non-contact safety switches designed for use
in many machine guarding applications, the Stainless steel housing can be selected, the switches and
actuator are fully sealed to IP67 and can often be used in wet or dusty environments, with the correct
installation, the safety switches comply with the guidelines given in ISO13849-1 with 2NC safety switch
and 1NO auxiliary switches, the magnetic actuator with SUS316L material housing.
Feature
1. Non-contact safety switches
2. Up to three contacts
3. 10 -24mm operating distance
4. Up to 400mA switching current
5. IP 67 /IP69K
6. Stainless steel housing
7. CE approvals
Applications
Can used in forming and filling (aluminum steel and plastic)
Pick and place packaging equipment and Semi-conduction equipment
Gun turret position control, door and hatch open/closed monitoring.
Pick and place/assembly equipment
Plastic molding equipment and Printing machinery
Aircraft landing Gear and Mass transit equipment.
Woodworking machinery
Textile machine
Specifications
Series name | MPSS |
Product tape | Safety safety switch |
Actuator | Magnetic non-contact switches |
Switches mode | 2N.C safety and 1N.O auxiliary |
Operating distance range | 10-25mm |
Voltage | 30Vdc/400mA resistive |
Housing material | Stainless steel SS304 |
Housing type | Switch and actuator |
Shock | 10g |
Vibration | 10-100Hz |
Sealing | IP67 |
Operating temp. range | -10 to 60ºC |
Cable length | 0.5 m prewired with M12 pin8 |
approvals | CE |
Dimension
Mounting
The FR range of safety switches can approach each other from most angles. When the guard is closed the targets on the printed face of the switch and actuator must be aligned.
Mount the switch on to the machine frame and the actuator on to the opening edge of the door.
Use the tamper proof screws provided to make the installation more secure.
Do not use the safety switch as a door stop. Leave a minimum of 50 mm between any adjacent switches.
EN 14119
Provides some mounting suggestions, see example opposite.
Connections & Fuses
Switching Characteristics
Photos