Magnetic Coded Safety Switches Non-Contact

Products

HomeHome / Products / FUSE CONTACT / Details
Magnetic Coded Safety Switches Non-Contact

Magnetic Coded Safety Switches Non-Contact

MPSS series Magnetic safety switches Description MPSS series safety switches are magnetically operated, non-contact safe

Send your inquiry

DESCRIPTION

Basic Info
Model NO. MPSS Series
Housing Stainless Steel SUS316L
Transport Package Carton
Trademark Yuanben
Origin Shanghai
HS Code 85299050
Production Capacity 50, 000PCS/Year
Product Description

MPSS series Magnetic safety switches

Description

MPSS series safety switches are magnetically operated, non-contact safety switches designed for use

in many machine guarding applications, the Stainless steel housing can be selected, the switches and

actuator are fully sealed to IP67 and can often be used in wet or dusty environments, with the correct

installation, the safety switches comply with the guidelines given in ISO13849-1 with 2NC safety switch

and 1NO auxiliary switches, the magnetic actuator with SUS316L material housing.

Feature

1. Non-contact safety switches

2. Up to three contacts

3. 10 -24mm operating distance

4. Up to 400mA switching current

5. IP 67 /IP69K

6. Stainless steel housing

7. CE approvals

Applications

Can used in forming and filling (aluminum steel and plastic)

Pick and place packaging equipment and Semi-conduction equipment

Gun turret position control, door and hatch open/closed monitoring.

Pick and place/assembly equipment

Plastic molding equipment and Printing machinery

Aircraft landing Gear and Mass transit equipment.

Woodworking machinery

Textile machine


Specifications

Series nameMPSS
Product tapeSafety safety switch
Actuator Magnetic non-contact switches
Switches mode2N.C safety and 1N.O auxiliary
Operating distance range10-25mm
Voltage30Vdc/400mA resistive
Housing materialStainless steel SS304
Housing typeSwitch and actuator
Shock 10g
Vibration10-100Hz
SealingIP67
Operating temp. range-10 to 60ºC
Cable length0.5 m prewired with M12 pin8
approvalsCE

Safety Related Data Note 1: Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years. Suitable for performance level applications PLe according to ISO 13849-1. (SIL 3 or SIL 2 according to IEC 62061)
Dimension

Magnetic Coded Safety Switches Non-Contact


Mounting
The FR range of safety switches can approach each other from most angles. When the guard is closed the targets on the printed face of the switch and actuator must be aligned.

Mount the switch on to the machine frame and the actuator on to the opening edge of the door.

Use the tamper proof screws provided to make the installation more secure.

Do not use the safety switch as a door stop. Leave a minimum of 50 mm between any adjacent switches.

EN 14119

Provides some mounting suggestions, see example opposite.

Magnetic Coded Safety Switches Non-Contact


Connections & Fuses

Magnetic Coded Safety Switches Non-Contact

Switching Characteristics

Magnetic Coded Safety Switches Non-Contact


Photos